<LOGO>
FM Transmitter Measurement Report
Created: 2024-06-06 04-01-54
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
104.70 MHz 5/5, 49 dBuV R-PCE
Pilot RDS Phase Difference
6.1 kHz 2.7 kHz -89 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 2,0 kHz
MIN Hold Max. Samples at Total Samples % above 77,0 kHz
9 kHz 39 kHz 18964 0,0686
Modulation Power
Limit Measuring Tolerance
0,0 dBr 0,2 dBr
MIN AVE MAX % above 0,2 dBr
-2,4 dBr -1,46 dBr -0,8 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"R-PCE " 280C 9 (Varied) 1 0 1 5 4:01, 6.06.2024
RT
"Cesky rozhlas Pardubice - zijeme tu s vami "
AF EON
88.9, 93.7, 98.6, 101.0, 102.4, 103.3, 104.7 MHz -
FM Scope Max at: 39 kHz MIN: 9 kHz % above 77 kHz: 0,0686 Acquired: 2024/06/06 4:01:51 Total samples: 18964 Equivalent time: 0:15:48 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 200 400 600 800
FM Scope MAX: -0,8 dBr MIN: -2,4 dBr AVE: -1,46 dBr % above 0,2 dBr: 0,0 Last value: -0,9 dBr (2024/06/06 4:01:50) 03:48 03:50 03:52 03:54 03:56 03:58 04:00 -4 -2 0 2 4 Pm [dBr] 0 5 Signal Quality